Lead in Air Sampling Kit Simple Operation Just turn on, calibrate, and sample No Battery Charging Easy access battery compartment
Complete sample integrity Compensates flow for changes in back pressure and temperature Low battery shut-off when battery level too low to maintain compensated flow LED indicates pump running, restricted flow (flow fault), and battery status Rugged RFI-shielded case User option flow fault shutdown CE approved
Ideal for lead and asbestos abatement sampling Designed for sampling applications that do no require intrinsic safety
Ideal for emergency response Ready for immediate use No down time for battery charging Easily stored without maintenance Personal Sampling from 5 to 3000 ml/min The AirLite sample pump is economically designed for personal sampling of asbestos, lead, and other airborne contaminants in environments not requiring intrinsic safety approvals. Powered by economical, disposable AA alkaline batteries, the AirLite provides run times greater than 8 hours in the 5 to 500 and 750 to 3000 ml/min flow ranges with full back pressure compensation. Automatic features ensure accurate air volumes, while an internal sensor corrects flow for changes in temperature. The bright LED indicates pump and battery status. AirLite is small and lightweight for easy attachment to a worker's belt where it won't interfere with worker activity. Performance Profile Compensated Flow Range: 5 ml/min to 3000 L/min, 5% Back Pressure Range: below 1.5 L/min > 30 inches water below 2.0 L/min > 20 inches water below 2.5 L/min > 15 inches water below 3.0 L/min > 10 inches water Compensated Temp. Range: 5 to 50 C Power: Three standard AA alkaline batteries Indicator Functions: Flashing LED Slow flash = normal run Fast flash = flow fault Double flash = low battery, approximately one-hour run-time remaining Four flashes every six seconds = pump shutdown due toflow fault Run-time (new batteries): 8.5 hours @ 1 L/min, 25 inches water back pressure 10 hours @ 2.5 L/min, 15 inches waterback pressure Case: Plastic, RFI-shielded Dimensions: 4.63 x 3 x 2.25 in (11.8 x 7.6 x 5.7 cm) includes inlet and belt clip Weight: 12 oz (340 gm)
About.....Low Flow Sampling The AirLite Sample Pump becomes a fully versatile sampler when combined with the low flow adapter kit. The kit's Constant Pressure Controller (CPC) accessory expands the AirLite's flow range capability to include the 5 to 500 ml/min range.
The Advantage
Economical Battery Operation. The AirLite Sample Pump operates on three disposable AA alkaline batteries that can be purchased at your local grocery store. Run times range from 8 to 12 hours depending on battery brand. Available for immediate use no need to maintain batteries or charge before sampling. Pump Run Time in Hours with Alkaline Batteries Following are typical run times achieved when using new AA Alkaline batteries. Data is sorted by type of sample media. All run times are listed in hours. Mixed Cellulose (MCE) filter, 0.8 m pore size Filter Diameter 37 mm 37 mm 37 mm 25 mm 25 mm Flow Rate 1 L/min 2 L/min 2.5 L/min 1 L/min 2 L/min Duracel Standard 23.5 14.5 13.5 18.5 10.5 Rayovac Maximum 20.0 16.5 14.0 16.5 11.0 Walmart EverActive 24.0 16.0 10.5 18.0 10.5 Eveready Alkaline 20.0 14.0 13.0 17.0 Not tested
Polyvinyl Chloride (PVC) filter, 0.8 m pore size Filter Diameter 37 mm 37 mm 37 mm 25 mm 25 mm Flow Rate 1 L/min 2 L/min 2.5 L/min 1 L/min 2 L/min Duracel Standard 23.5 15.5 17.0 23.0 10.5 Rayovac Maximum 29.5 16.5 14.0 18.5 13.0 Walmart EverActive 24.5 20.5 15.5 20.5 11.5
Glass fiber filter Filter Diameter 37 mm 37 mm 37 mm 37 mm 25 mm 25 mm 25 mm 25 mm Flow Rate 1 L/min 2 L/min 2.5 L/min 3 L/min 1 L/min 2 L/min 2.5 L/min 3 L/min Energizer 29.5 18.0 21.0 18.5 29.0 18.5 18.5 12.0 Rayovac Maximum 26.5 23.5 23.0 14.0 9.5 19.5 14.5 13.5 Walmart EverActive 33.5 24.5 17.5 19.0 26.0 20.0 14.5 14.0
Lead in Air Sampling Kit
For easy sampling of lead in air, order the SKC Lead in Air Sampling Kit 224-4122. This kit contains an easy-to-use AirLite Sample Pump, 50 filter cassettes for collecting lead particles from the air, a filter cassette holder to secure the filter cassette during sampling, and a step-by-step guide for sampling lead in air. Samples must be sent to a qualified laboratory for analysis. See Ordering Information below.
|